High/Very High Risk. The Softform Premier Active 2 retains properties as a high-risk static mattress but should clinical judgement determine that the patient requires stepping up to a dynamic surface. A discrete pump can be fitted to the air insert transforming the mattress into a dynamic surface and delivering additional levels of pressure relief.
▶Watch it in actionSpecifications & funding report dataWarranty, ISO, ARTG, service life and lead times — everything for your report↓From the manufacturer
**A hybrid: a high-risk reactive foam mattress that becomes a very-high-risk alternating surface when a pump is fitted.** That is the point of it, and it solves a real problem. Normally, stepping a patient up from a static mattress to an alternating one means swapping the whole mattress — a manual handling job, a transfer for a patient who is by definition deteriorating, and a second mattress to store. Here the **same mattress stays on the bed** and a discrete pump is added or removed. Rated **High Risk** without the pump, **Very High Risk** with the RX control unit. That also means it can be stepped back **down** just as easily when skin improves, which rarely happens in practice because the swap is too much trouble. **In a power failure the patient is still lying on a high-risk pressure-reducing foam surface.** This is the single most important difference from a pure air mattress, which deflates toward the bed platform when power is lost or the pump fails. For a home setting with unreliable power, or where a pump fault might not be noticed overnight, that is a substantial safety margin. **Air cells alternate on a 10-minute cycle** to promote tissue recovery and redistribute load. **The air system sits beneath the foam insert**, not above it — which markedly reduces the risk of a sharps puncture. Anywhere subcutaneous injections or sharps are in use around the bed, that is worth knowing. **Single-piece foam U-core.** The raised side walls give something firm to sit on at the edge, which supports transfers — an edge that collapses under a patient perching to stand is a genuine fall mechanism, and most pressure mattresses have exactly that problem. **Two-way stretch PU waterproof cover.** Two-way stretch is what lets the cover move with the patient rather than bridging across the surface — a cover that doesn't stretch defeats immersion and is a common, easily missed reason a good mattress underperforms. It also reduces shear and friction at the skin. Cover construction for infection control: **high-frequency welded seams**, a **full-length flap concealing the zip**, and a toughened PU-coated base. Water penetration resistance **35 kPa minimum to BS 3424-26**, still 35 kPa after **20,000 cycles** of Martindale abrasion testing to EN ISO 5470-2 — that is a durability figure worth quoting where the mattress will be cleaned repeatedly. **Does not require turning**, which removes a recurring manual handling task. **User weight 247.6 kg.** Mattress 1970 × 880 × 152 mm, 14 kg. Control unit 275 × 155 × 105 mm, 1.75 kg. **Check the 152 mm depth against your bed's side rails** — the Invacare CS8, for instance, requires mattress depth between 100 and 170 mm when rails are fitted, so this pairs correctly. Not every combination does.
We aim to make our range as accessible as possible. Some products may not be available in all areas — please contact BMS Plus to confirm availability and discuss suitable options.
Product detail
Single
King Single
Bariatric
Everything needed to justify this equipment in an NDIS, DVA or Home Care Package report.